Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.214
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 182, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532333

RESUMO

OBJECTIVE: To evaluate the early and mid-term outcomes of open repair in patients with thoracoabdominal aortic aneurysm (TAAA) after thoracic endovascular aortic repair (TEVAR). METHODS: This was a retrospective single center study. Data were retrospectively collected and analyzed for consecutive patients undergoing open TAAA repair (TAAAR) after TEVAR from November 2016 to June 2021. Indications for TAAAR included aneurysm progression due to endoleak, persisted false lumen perfusion, proximal/distal disease progression, and aorta rupture. The risk factor of operative mortality was analyzed by multivariable logistic regression model and the survival was evaluated by Kaplan-Meier. RESULTS: Sixty-three patients who met the inclusion criteria for the study were identified. The mean age at TAAAR was 41 ± 12 years and 43 (68.3%) were male. Marfan syndrome (MFS) was presented in 39 patients (61.9%). 60 (95.2%) patients presented with post-dissection aneurysm and 3 (4.8%) patients with degenerative aneurysm. The extent of TAAA was Crawford I in 9 (14.3%), II in 22 (34.9%), III in 23 (36.5%), and IV in 9 (14.3%). Emergent TAAAR was done in 10 (15.9%) patients, and deep hypothermic circulatory arrest was used in 22 (34.6%). Endograft was explanted in 31 (49.2%). Operative mortality was 11 (17.5%). Stroke, paraplegia, and acute kidney failure occurred in 5 (7.9%), 7 (11.1%), and 6 (9.5%) patients, respectively. Pulmonary complications occurred in 19 (30.2%) patients. The estimated survival was 74.8 ± 4.9% at 5 years. Late reoperations were performed in 2 patients at 2.5 years and 1.3 years, respectively. CONCLUSIONS: In this series of TAAA after TEVAR, TAAAR was related with a high risk of operative mortality and morbidity and the midterm outcomes represented a durable treatment and were respectable.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias
2.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459863

RESUMO

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
3.
BMC Cardiovasc Disord ; 24(1): 124, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408908

RESUMO

BACKGROUND: This study aims to compare the clinical effects of two distinct surgical approaches, namely 3D printing-assisted extracorporeal pre-fenestration and Castor integrated branch stent techniques, in treating patients with Stanford type B aortic dissections (TBAD) characterized by inadequate proximal landing zones. METHODS: A retrospective analysis was conducted on 84 patients with type B aortic dissection (TBAD) who underwent thoracic endovascular aortic repair (TEVAR) with left subclavian artery (LSA) reconstruction at our center from January 2022 to July 2023. Based on the different surgical approaches, the patients were divided into two groups: the group assisted by 3D printing for extracorporeal pre-fenestration (n = 44) and the group using the castor integrated branch stent (n = 40). Clinical indicators: including general patient information, operative time, surgical success rate, intraoperative and postoperative complication rates, re-intervention rate, and mortality, as well as postoperative aortic remodeling, were compared between the two groups. The endpoint of this study is the post-TEVAR mortality rate in patients. RESULTS: The surgical success rate and device deployment success rate were 100% in both groups, with no statistically significant difference (P > 0.05). However, the group assisted by 3D printing for extracorporeal pre-fenestration had a significantly longer operative time (184.20 ± 54.857 min) compared to the group using the castor integrated branch stent (152.75 ± 33.068 min), with a statistically significant difference (t = 3.215, p = 0.002, P < 0.05). Moreover, the incidence of postoperative cerebral infarction and beak sign was significantly lower in the group assisted by 3D printing for extracorporeal pre-fenestration compared to the castor-integrated branch stent group, demonstrating statistical significance. There were no significant differences between the two groups in terms of other postoperative complication rates and aortic remodeling (P > 0.05). Notably, computed tomography angiography images revealed the expansion of the vascular true lumen and the reduction of the false lumen at three specified levels of the thoracic aorta. The follow-up duration did not show any statistically significant difference between the two groups (10.59 ± 4.52 vs. 9.08 ± 4.35 months, t = 1.561, p = 0.122 > 0.05). Throughout the follow-up period, neither group experienced new endoleaks, spinal cord injuries, nor limb ischemia. In the castor-integrated branch stent group, one patient developed a new distal dissection, prompting further follow-up. Additionally, there was one case of mortality due to COVID-19 in each group. There were no statistically significant differences between the two groups in terms of re-intervention rate and survival rate (P > 0.05). CONCLUSION: Both 3D printing-assisted extracorporeal pre-fenestration TEVAR and castor-integrated branch stent techniques demonstrate good safety and efficacy in treating Stanford type B aortic dissection with inadequate proximal anchoring. The 3D printing-assisted extracorporeal pre-fenestration TEVAR technique has a lower incidence of postoperative cerebral infarction and beak sign, while the castor-integrated branch stent technique has advantages in operative time.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Stents/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Complicações Pós-Operatórias/terapia , Aortografia/métodos , Infarto Cerebral/complicações
4.
J Surg Res ; 296: 516-522, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38330677

RESUMO

INTRODUCTION: Recent data suggests that infrarenal abdominal aortic aneurysm (AAA) endovascular repair (EVAR) with large diameter grafts (LGs) may have a higher risk of endoleak and reintervention. However, this has not been studied extensively for fenestrated endovascular aneurysm repair (fEVAR). We, therefore, sought to evaluate the outcomes of patients undergoing fEVAR with large-diameter endografts. METHODS: Patients from the national Vascular Quality Initiative registry who underwent fEVAR for intact juxtarenal AAA were identified. Patients with genetic causes for aneurysms, those with prior aortic surgery, and those undergoing repair for symptomatic or ruptured aneurysms were excluded. Rates of endoleaks and reintervention at periprocedural and long-term follow-up timepoints (9-22 mo) were analyzed in grafts 32 mm or larger (LG) and were compared to those smaller than 32 mm (small diameter graft). RESULTS: A total of 693 patients (22.8% LG) were identified. Overall, demographic variables were comparable except LG exhibited a more frequent history of coronary artery disease (32.9% versus 25.4%, P = 0.037). There were no significant differences in the rates of endoleak at procedural completion. Overall survival at 5 y was no different. The rate of reintervention at 1 y was also no different (log-rank P = 0.86). CONCLUSIONS: While graft size appears to have an association with outcomes in infrarenal aneurysm repair, the same does not appear to be true for fEVAR. Further studies should evaluate the long-term outcomes associated with LG which could alter the approach to repair of AAA with large neck diameters traditionally treated with standard infrarenal EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/cirurgia , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese
6.
J Vasc Surg ; 79(2): 207-216.e4, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37804955

RESUMO

OBJECTIVE: The aim of this study was to investigate the outcomes of primary determinate and indeterminate target vessel endoleaks (TVELs) after fenestrated-branched endovascular aortic repair (F-BEVAR). METHODS: We conducted a single-center retrospective study (2014-2023) on F-BEVAR for thoracoabdominal (TAAAs) or pararenal aortic aneurysms (PRAAs). TVELs were classified as "primary" if present at the first postoperative computed tomography angiogram. Endoleaks were defined "determinate" (dELs) if the cause (type Ic or IIIc) and implicated target vessel were identifiable and "indeterminate" (iELs) if contrast enhancement was detectable at the level of fenestrations/branches without any evident source. Endoleaks involving multiple inflows (type II and target vessels) were defined as "complex" (cELs). Endpoints were endoleak spontaneous resolution, 1-year aneurysm sac failure to regress (>5 mm diameter decrease), and 4-year endoleak-related secondary interventions. Kaplan-Meier estimates and Cox regression were used for the analysis. RESULTS: There were 142 patients with JRAAs/PRAAs (n = 85; 60%) or TAAAs (n = 57; 40%), with 513 target arteries incorporated through a fenestration (n = 294; 57%) or directional branch (n = 219; 43%). Fifty-nine primary TVELs (12%) were identified in 35 patients (25%), a dEL in 20 patients (14%) and iEL in 15 (11%); 22 (15%) had a determinate or indeterminate cEL. Overall spontaneous resolution rate was 75% (95% confidence interval [CI], 51%-87%) at 4 years. cELs (odds ratio [OR], 5.00; 95% CI, 1.10-49.4; P < .001) and iELs after BEVAR (OR, 9.43; 95% CI, 3.41-56.4; P = .002) were more likely to persist >6 months, and persistent forms were associated with sac failure to regress at 1 year (OR, 1.72; 95% CI, 1.03-12.59; P = .040). Overall freedom from endoleak-related reinterventions was 85% (95% CI, 79%-92%) at 4 years, 92% (95% CI, 87%-97%) for those without primary TVELs and 62% (95% CI, 46%-84%) for those with any primary TVEL (P < .001). In particular, cELs (hazard ratio, 1.94; 95% CI, 1.4-18.81; P = .020) were associated with an increased need for reintervention. In case a secondary intervention was needed, iEL or cEL had an increased risk for multiple secondary procedures (hazard ratio, 2.67; 95% CI, 1.22-10.34; P = .034). CONCLUSIONS: Primary TVELs are frequent after F-BEVAR, and a clear characterization of the endoleak source by computed tomography angiogram is not possible in 40% of patients. Most primary TVELs spontaneously resolve, but during follow-up, patients with any primary TVEL experience a worsened freedom from endoleak-related reinterventions that is mostly driven by persistence of cELs and post-BEVAR iELs. Multiple secondary procedures may be required in case of iELs or cELs.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Prótese Vascular/efeitos adversos
7.
Vasc Endovascular Surg ; 58(3): 343-349, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37944002

RESUMO

BACKGROUND: When treating aortic aneurysm patients with complex anatomical features, preprocedural planning aided by 3D-printed models offers valuable insights for endovascular intervention. This study highlights the use of stereolithographic (SLA) 3D printing to fabricate a phantom of a challenging aortic arch aneurysm with a complex neck anatomy. CLINICAL CASE: A 75-year-old female presented with a 58 mm descending thoracic aortic aneurysm (TAA) extending to the distal arch, involving the left subclavian artery (LSA) and the left common carotid artery (LCCA). The computed tomography (CT) scans underwent scrutiny by radiology and vascular teams. Nevertheless, the precise spatial relationships of the ostial origins proved to be challenging to ascertain. To address this, a patient-specific phantom of the aortic arch was fabricated utilizing an SLA printer and a biomedical resin. The thoracic endovascular aortic repair (TEVAR) procedure was simulated using fluoroscopy on the phantom to enhance procedural preparedness. Subsequently, the patient underwent a right carotid-left carotid bypass and a right carotid-left subclavian bypass. After a 24-hour interval, the patient underwent the TEVAR procedure, during which a 37 mm × 150 mm stent graft (CTAG, WL Gore and Associates, Flagstaff, AZ, USA) and a 40 mm × 200 mm stent graft (CTAG, WL Gore and Associates, Flagstaff, AZ, USA) were deployed, effectively covering the LSA and LCCA. Notably, the aneurysm exhibited complete sealing, with no indications of endoleaks or graft infoldings. At the 12-month follow-up, the patient remains in good health, with no evidence of endoleaks or any other surgery-related complication. CONCLUSION: This report showcases the successful use of a 3D-printed endovascular phantom in guiding the decision-making process during the preparation for a TEVAR procedure. The simulation played a pivotal role in selecting the appropriate stent graft, ensuring an intervention protocol optimized based on the patient-specific anatomy.


Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Feminino , Humanos , Idoso , Correção Endovascular de Aneurisma , Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Endoleak/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma/cirurgia , Estudos Retrospectivos
8.
J Neurosurg ; 140(2): 436-440, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37877979

RESUMO

OBJECTIVE: The object of this study was to compare the efficacy and safety profile of the Pipeline embolization device (PED)/Pipeline Flex embolization device (PED Flex) with that of the Pipeline Flex embolization device with Shield Technology (PED Shield). After introducing the first-generation PED and the second-generation PED Flex with its updated delivery system, the PED Shield was launched with a synthetic layer of phosphorylcholine surface modification to reduce thrombogenicity. METHODS: This is a retrospective review of unruptured aneurysms treated with PED/PED Flex versus PED Shield between 2017 and 2022 at the authors' institution. Patients with ruptured aneurysms, adjunctive treatment, failed flow diverter deployment, and prior treatment of the target aneurysm were excluded. Baseline characteristics were collected for all patients, including age, sex, past medical history (hypertension, hyperlipidemia, diabetes mellitus), smoking status, aneurysm location, and aneurysm dimensions (neck, width, height) and morphology (saccular, nonsaccular). The primary outcome was procedural and periprocedural complication rates. RESULTS: The study cohort comprised 200 patients with 200 aneurysms, including 150 aneurysms treated with the PED/PED Flex and 50 treated with the PED Shield. With respect to intraprocedural and periprocedural complications, length of stay, length of follow-up, and functional outcome at discharge, there was no significant difference between the two cohorts. At the midterm follow-up, the rate of in-stent stenosis (PED/PED Flex: 14.2% vs PED Shield: 14.6%, p = 0.927), aneurysm occlusion (complete occlusion: 79.5% vs 80.5%, respectively; neck remnant: 4.7% vs 12.2%; dome remnant: 15.7% vs 7.3%; p = 0.119), and the need for retreatment (5.3% vs 0%, p = 0.097) were comparable between the two cohorts. CONCLUSIONS: This study suggests that, as compared to first- and second-generation PED and PED Flex, the third-generation PED Shield offers similar rates of complications, aneurysm occlusion, and in-stent stenosis at the midterm follow-up.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Constrição Patológica , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/etiologia , Embolização Terapêutica/métodos , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
9.
J Neurosurg ; 140(1): 144-152, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439478

RESUMO

OBJECTIVE: Histopathological studies of aneurysms after coil embolization showed that thrombus formation during the first month after endovascular treatment (EVT) played an important role in the healing process. The authors hypothesized that dedicated T1-weighted imaging may be used to predict stable aneurysms by visualizing the thrombus status within coil-treated aneurysms. Therefore, this study investigated the relationship between the signal intensity (SI) of the intraaneurysmal sac after coil embolization and aneurysm stability. METHODS: The study population included 82 patients with 86 aneurysms who underwent T1-weighted 3D black-blood fast spin-echo (T1 CUBE) imaging within 1 month after coil embolization between 2019 and 2022. The relative SI of a coil-treated aneurysm (RSIcoiled) was calculated as follows: the mean SI of the intraaneurysmal sac/the mean SI of the genu of the corpus callosum. Aneurysms with enlarged remnants on MR angiography (MRA) within 6 months after EVT were defined as recurrence, while a decrease of intraaneurysmal flow on MRA was defined as improved embolization status. Stable aneurysms were defined as improvement or no change in embolization status 6 months after coil embolization. The volume embolization ratio (VER) was calculated as the ratio of the packed coil volume to the aneurysm volume. Differences between stable and recurrent aneurysms were examined. All aneurysms were divided into high and low RSIcoiled groups based on the cutoff value of RSIcoiled, and differences between the two groups were also evaluated. RESULTS: Recurrence was confirmed for 26 of 86 aneurysms. A univariable analysis showed that small aneurysms, high VER, and high RSIcoiled were associated with aneurysm stability. In the receiver operating characteristic curve analysis, the optimal cutoff value for RSIcoiled to differentiate stable from recurrent aneurysms was 0.54. The cutoff value for RSIcoiled was selected as 0.50 (sensitivity 0.77, specificity 0.70) because it was half the value of the SI of the corpus callosum and close to the optimal cutoff value. In a multivariable analysis, RSIcoiled > 0.50 (OR 8.1, 95% CI 2.5-27) remained a significant factor for aneurysm stability. The high RSIcoiled group showed a higher rate of an improved embolization status (26% vs 6.1%, p = 0.022) and stable aneurysms (85% vs 15%, p = 0.0002). CONCLUSIONS: RSIcoiled was associated with postcoiling aneurysm stability. High RSIcoiled might imply intraaneurysmal thrombus formation associated with the healing process of coil-treated aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Trombose , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/etiologia , Prótese Vascular/efeitos adversos , Angiografia por Ressonância Magnética , Embolização Terapêutica/métodos , Resultado do Tratamento , Estudos Retrospectivos
10.
Ann Thorac Surg ; 117(2): 336-343, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37769702

RESUMO

BACKGROUND: The safety and effectiveness of the RelayPro endograft (Terumo Aortic) was assessed for the treatment of acute, complicated type B aortic dissection (TBAD). METHODS: A prospective pivotal trial analyzed a primary end point of all-cause mortality at 30 days. Secondary end points included technical success, major adverse events (disabling stroke, renal failure, and paraplegia/paralysis), endoleaks, patency, rupture, device integrity, false lumen perfusion, reinterventions, aortic expansion, and migration evaluated to 5 years. RESULTS: The study involved 22 United States centers and enrolled 56 patients (mean age, 59.5 ± 11.4 years) from 2017 to 2021; of whom, 73.2% were men and 53.6% were African American. TBAD was complicated by malperfusion of the kidneys (51.8%), lower extremities (35.7%), and viscera (33.9%), and rupture (10.7%). Dissection extended proximally to zones 1/2 (14.3%) and zone 3 (78.6%) and distally to the iliac arteries (67.3%). Most procedures were percutaneous (85.5%). Technical success was 100%. Median hospitalization was 7 days (interquartile range, 5-12 days). All-cause mortality at 30 days was 1.8% (1 of 56; upper 95% CI, 8.2%; P < .0001). Seven major adverse events occurred in 6 patients (10.7%), consisting of paraplegia (n = 3), paraparesis (n = 2), disabling stroke (n = 1), and renal failure (n = 1). All paraplegia/paraparesis resolved with lumbar drainage. Kaplan-Meier analysis estimated a freedom from major adverse events of 89.1% at each interval from 30 days to 3 years. There was 1 endoleak (Type Ia), 2 retrograde dissections, and aortic diameter growth occurred in 2. There has been no rupture, fistula, component separation, patency loss, stenosis, kinking, twisting, bird beak, loss of device integrity, or fracture. CONCLUSIONS: RelayPro is safe and effective in acute, complicated TBAD. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Renal , Acidente Vascular Cerebral , Masculino , Humanos , Estados Unidos , Pessoa de Meia-Idade , Idoso , Feminino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Estudos Prospectivos , Resultado do Tratamento , Stents/efeitos adversos , Dissecção Aórtica/cirurgia , Endoleak/etiologia , Paraplegia/etiologia , Estudos Retrospectivos , Insuficiência Renal/etiologia , Acidente Vascular Cerebral/etiologia , Paraparesia/complicações , Procedimentos Endovasculares/efeitos adversos
11.
J Vasc Interv Radiol ; 35(1): 25-31, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37776993

RESUMO

PURPOSE: To assess the safety and effectiveness of a rotational mechanical atherothrombectomy device in patients with symptomatic iliac limb occlusion after abdominal endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: A retrospective analysis was conducted on patients who underwent rotational mechanical thrombectomy using the Rotarex S device for symptomatic acute, subacute, or chronic graft limb thrombosis at 5 vascular centers between 2017 and 2021. This study comprised 23 male patients with a mean age of 74.5 years (SD ± 7.2) at the time of the procedure. The clinical presentation of the patients varied, with 1 patient experiencing acute limb ischemia and 11 patients (47.8%) experiencing disabling intermittent claudication. The remaining patients developed chronic limb-threatening ischemia after iliac limb occlusion. Early outcomes included technical success, postprocedural complications, and periprocedural mortality. Follow-up evaluations encompassed primary patency, patient survival, freedom from reintervention, and the need for surgical conversion. RESULTS: Technical success was achieved in all cases, with no occurrences of distal embolization during or after the procedure, and no periprocedural deaths were reported. Endograft relining was performed in 82.6% of patients to establish a new, nonthrombogenic surface within the graft. Over a median follow-up period of 8 months (interquartile range, 3-16 months), 2 patients experienced iliac limb reocclusion. No deaths or other reinterventions occurred during the observational follow-up period. CONCLUSIONS: Rotational mechanical thrombectomy for iliac limb occlusion after EVAR appears to be both safe and effective. This technique may uncover intraluminal defects contributing to graft occlusion and enable their resolution within the same procedure.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese , Stents/efeitos adversos , Trombectomia/efeitos adversos , Itália
12.
Infect Dis Now ; 54(1): 104792, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37777183

RESUMO

OBJECTIVES: Fungal prosthetic vascular graft infections are rare and mainly supra-inguinal. Current guidelines are based on the few studies that have specifically investigated this population, with few risk factors described. The objective of this study is to compare fungal and non-fungal supra-inguinal prosthetic vascular graft infections (PVGI), describing their specificities, identifying risk factors, and evaluating outcomes. PATIENTS AND METHODS: This is a single-center retrospective cohort study carried out at the Pitié-Salpêtrière Hospital in Paris, including all patients who were treated for a supra-inguinal PVGI between January 1st, 2009 and February 28th, 2021. Preoperative, intraoperative and postoperative data were compared between fungal and non-fungal PVGI. RESULTS: Out of the 475 patients screened, 148 developed a supra-inguinal PVGI: 32 fungal and 116 non-fungal. Factors independently associated with fungal PVGI were presence of a prostheto-digestive fistula (OR 5.98; 95% CI 2.29-15.62) and preoperative antibiotic therapy of seven days or more (OR 2.87; 95% CI 1.12-7.38). Mortality rate at 180 days was significantly higher for fungal as compared to non-fungal PVGIs (38% vs. 16% p = 0.009) and for fungal PVGI with prostheto-digestive fistula. However, there was no statistically significant relation between mortality due to prostheto-digestive fistula in contrast with fungal PVGI alone (p = 0.21). CONCLUSION: Prostheto-digestive fistula was strongly associated with fungal PVGI, which leads us to suggest that in such cases, an anti-fungal agent should be prescribed.


Assuntos
Implante de Prótese Vascular , Fístula , Humanos , Implante de Prótese Vascular/efeitos adversos , Estudos de Coortes , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fístula/etiologia
13.
Vasc Endovascular Surg ; 58(3): 255-262, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37837310

RESUMO

OBJECTIVES: The management of type 1B endoleaks following endovascular aortic aneurysm repair (EVAR) can be challenging. The Heli-FX Endoanchor system effectively treats proximal type 1A endoleaks but has not been used for type 1B common iliac artery endoleaks. This study demonstrates that it is both safe and effective in being used in the common iliac artery (CIA) limb of an EVAR. METHODS: A retrospective review of patients identified through coding and medical records was performed to extract information on demographics, aneurysmal features, operative features, and postoperative outcomes. This was then collated and analysed thoroughly and compared to existing research. RESULTS: Four patients with six type 1B CIA endoleaks were treated with Heli-FX Endoanchors in the CIA limbs of EVAR grafts. There was 100% technical success rate with complete exclusion of the endoleaks at 6 months. With mean follow up of 714 days, there were no Endoanchor-specific complications. One patient required explantation of the aortic endograft due to contralateral limb fracture, where it was found that an Endoanchor had penetrated the common iliac vein, requiring primary closure. CONCLUSIONS: Heli-FX Endoanchors were effective within this cohort of patients, though key risks were identified. Adjacent anatomy to the CIA must be considered, which also have nearly half the arterial thickness compared to the aorta. Pre-operative planning is essential given the theoretical risk of placing Endoanchors.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Fatores de Risco
14.
Ann Vasc Surg ; 99: 332-340, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37839654

RESUMO

BACKGROUND: The endovascular repair of infrarenal abdominal aortic aneurysms can be performed with a wide variety of devices. Many of these grafts elevate the aortic bifurcation which can limit future repairs if the graft material fails thereby creating a type III endoleak to aorto-uniliac grafts. Many manufacturers have grafts susceptible to this, but we have seen this in the Medtronic AneuRx graft. Our goal is to provide technical details and outcomes regarding a novel technique to reline these grafts while maintaining inline flow to the iliac arteries. METHODS: This was a single-institution review of patients who had endoleaks requiring intervention after a previously placed graft with an elevated aortic bifurcation. Primary outcomes included technical success defined as placement of all planned devices, resolution of type III endoleak, aneurysm size at follow-up, and requirement of reintervention. Secondary outcomes included 30-day complications, aneurysm-related mortality, and all-cause mortality. Technical details of the operation include back-table deployment of an Ovation device, modification of the deployment system tether and pre-emptive placement of an up and over 0.014″ wire. The wire is placed up and over and hung outside the contralateral gate. Once the main body is introduced above the old graft, the 0.014" is snared from the contralateral side and externalized. The main body is then able to be seated at the bifurcation as the limb is not fully deployed and then device deployment is completed per instructions for use. RESULTS: Our study consists of 4 individuals, 3 of which had an abdominal aortic aneurysm initially managed with an AneuRx endovascular aneurysm repair and 1 with a combination of Gore and Cook grafts. All 4 patients were male with an average age of 84.5 years at time of reline. All patients had at least 10 years between initial surgery and reline at our institution. Primary outcomes revealed no type 1 or 3 endoleaks at follow-up, technical success was 100% and 1 patient required reintervention for aneurysm growth and type 2 endoleak. In terms of our secondary outcomes, there was 1 postoperative complication which was cardiac dysfunction secondary to demand ischemia, aneurysm-related mortality was 0% and all-cause mortality was 25% at average follow-up of 2.44 years. CONCLUSIONS: As individuals continue to age, there are more patients who would benefit from less invasive reinterventions following endovascular aneurysm repair. Whether this is due to aortic degeneration, stent migration, or stent material damage is not always known. In this study, we present an endovascular approach to treating type III endoleak patients with a previous graft and elevated aortic bifurcation using Ovation stent grafts and found no evidence of type 1 or 3 endoleaks on follow-up imaging. This approach may allow patients with type III endoleak the option of a minimally invasive, percutaneous approach where they previously would not have had one.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Correção Endovascular de Aneurisma , Fatores de Risco , Resultado do Tratamento , Stents/efeitos adversos , Desenho de Prótese
15.
Ann Vasc Surg ; 101: 62-71, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38154495

RESUMO

BACKGROUND: Endovascular treatment allows for the staging of thoracoabdominal aortic aneurysm repairs (eTAAAs) in an effort to decrease the risk of spinal cord ischemia (SCI), but data are limited. METHODS: We studied all eTAAAs in the Vascular Quality Initiative from 2014 to 2021. Inverse probability weighting was used to compare perioperative and long-term outcomes of staged and single-stage repairs. Thoracoabdominal life-altering events (TALEs) are the composite endpoint consisting of death/stroke/permanent SCI/permanent dialysis. RESULTS: There were 3,258 total operations during the study period. In total, 841 cases (26%) were staged repairs, and 2,417 (74%) were completed in a single stage, but in the cohort of patients with extensive aneurysms, 44% were staged. Staging methods included thoracic endograft (78%), branch (23%), and iliac (5%). Staged repairs were more often employed by high-volume surgeons at high-volume centers; for larger, more extensive aneurysms, with higher rates of prior aortic surgery. After adjustment, staged repair and single-stage treatment were associated with similar odds of all perioperative outcomes and including mortality, TALE, acute kidney injury, stroke, dialysis, and SCI, as well as long-term survival. This was consistent in the subgroups of patients with extensive aneurysms undergoing elective procedures. Of note, first-stage thoracic endografts were associated with 2.6% mortality, 7.3% TALE, 1.5% dialysis, and 4.1% SCI, and 25% of patients did not undergo a second stage. First-stage procedures accounted for one-third of perioperative complications including half of the deaths in the staged cohort. CONCLUSIONS: Staged eTAAA repairs were associated with similar perioperative and long-term complications to single-stage treatments. However, first stage procedures are associated with significant morbidity and mortality, and one-quarter of patients never complete their repairs. These data demonstrate the necessity of evaluating the outcomes of all patients planned for staged procedures, not only those who make it to the final stage. More data are needed as to the optimal method of spinal cord protection for these challenging aneurysms.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Acidente Vascular Cerebral , Humanos , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias , Fatores de Tempo , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/cirurgia , Acidente Vascular Cerebral/etiologia
16.
Ann Vasc Surg ; 101: 148-156, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38159719

RESUMO

BACKGROUND: Information regarding optimal revascularization and digestive tract repair in secondary aortoenteric fistula (sAEF) remains unclear. Thus, reporting treatment outcomes and presenting comprehensive patient details through a structured treatment approach are necessary to establish a treatment strategy for this rare, complex, and fatal condition. METHODS: We performed a single-center retrospective review of consecutive sAEF managed based on our in situ revascularization and intestinal repair strategy. The primary endpoint of this study was all-cause mortality, and secondary endpoints were the incidence of in-hospital complications and midterm reinfections. RESULTS: Between 2007 and 2020, 16 patients with sAEF, including 13 men (81%), underwent in situ revascularization and digestive tract repair. The median follow-up duration for all participants was 36 (interquartile range, 6-62) months. Among the participants, 81% (n = 13), 13% (n = 2), and 6% (n = 1) underwent aortic reconstruction with rifampin-soaked grafts, unsoaked Dacron grafts, and femoral veins, respectively. The duodenum was the most commonly involved site in enteric pathology (88%; n = 14), and 57% (n = 8) of duodenal breaks were repaired by a simple closure. Duodenum's second part-jejunum anastomosis was performed in 43% of patients (n = 6), and 19% of the patients (n = 3) died perioperatively. In-hospital complications occurred in 88% patients (n = 14), and the most frequent complication was gastrointestinal. Finally, 81% patients (n = 13) were discharged home. Oral antibiotics were administered for a median duration of 5.7 months postoperatively; subsequently, the participants were followed up carefully. Reinfection was detected in 6% of the patients (n = 1) who underwent reoperation without any complications. The 1-year and 3-year overall survival rates of participants were 75% (n = 12) and 75% (n = 9), respectively, and no sAEF-related deaths occurred, except perioperative death. CONCLUSIONS: Surgical intervention with contemporary management based on our vascular strategy and digestive tract procedure may be a durable treatment for sAEF.


Assuntos
Doenças da Aorta , Implante de Prótese Vascular , Fístula Intestinal , Fístula Vascular , Masculino , Humanos , Resultado do Tratamento , Prótese Vascular/efeitos adversos , Fístula Intestinal/diagnóstico por imagem , Fístula Intestinal/etiologia , Fístula Intestinal/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/complicações , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Estudos Retrospectivos , Duodeno/cirurgia , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia , Fístula Vascular/cirurgia
17.
J Vasc Surg ; 79(4): 941-947, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38101708

RESUMO

OBJECTIVE: Peripheral arterial infections are rare and difficult to treat when an in situ reconstruction is required. Autologous vein (AV) is the conduit of choice in many scenarios. However, cryopreserved arterial allografts (CAAs) are an alternative. We aimed to assess our experience with CAAs and AVs for reconstruction in primary and secondary peripheral arterial infections. METHODS: Data from patients with peripheral arterial infections undergoing reconstruction with CAA or AV from January 2002 through August 2022 were retrospectively analyzed. Patients with aortic- or iliac-based infections were excluded. RESULTS: A total of 42 patients (28 CAA, 14 AV) with a mean age of 65 and 69 years, respectively, were identified. Infections were secondary in 31 patients (74%) and primary in 11 (26%). Secondary infections included 10 femoral-femoral grafts, 10 femoropopliteal or femoral-distal grafts, five femoral patches, four carotid-subclavian grafts, one carotid-carotid graft, and one infected carotid patch. Primary infection locations included six femoral, three popliteal, and two subclavian arteries. In patients with lower extremity infections, associated groin infections were present in 19 (56%). Preoperative blood cultures were positive in 17 patients (41%). AVs included saphenous vein in eight and femoral vein in six. Intraoperative cultures were negative in nine patients (23%), polymicrobial in eight (21%), and monomicrobial in 22 (56%). Thirty-day mortality occurred in four patients (10%), two due to multisystem organ failure, one due to graft rupture causing acute blood loss and myocardial infarction, and one due to an unknown cause post-discharge. Median follow-up was 20 months and 46 months in the CAA and AV group, respectively. Graft-related reintervention was performed in six patients in the CAA group (21%) and one patient in the AV group (7%). Freedom from graft-related reintervention rates at 3 years were 82% and 92% in the CAA and AV group, respectively (P = .12). Survival rates at 1 and 3 years were 85% and 65% in the CAA group and 92% and 84% in the AV group (P = .13). Freedom from loss of primary patency was similar with 3-year rates of 77% and 83% in the CAA and AV group, respectively (P = .25). No patients in either group were diagnosed with reinfection. CONCLUSIONS: CAAs are an alternative conduit for peripheral arterial reconstructions when AV is not available. Although there was a trend towards higher graft-related reintervention rates in the CAA group, patency is similar and reinfection is rare.


Assuntos
Assistência ao Convalescente , Implante de Prótese Vascular , Humanos , Idoso , Estudos Retrospectivos , Reinfecção , Resultado do Tratamento , Alta do Paciente , Aloenxertos , Grau de Desobstrução Vascular , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Veia Safena/transplante , Fatores de Risco
18.
J Vasc Surg ; 79(5): 997-1004.e1, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38142945

RESUMO

OBJECTIVE: We compared the outcomes of patients treated with nonbare stents (NBS) and proximal bare stents (PBS) endografts with a proximal landing zone in the aortic arch during thoracic endovascular aortic repair (TEVAR). METHODS: We conducted a retrospective cohort, observational, multicenter study that included 361 consecutive TEVAR procedures undertaken between November 2005 and December 2021. TEVAR patients with both BS and NBS Relay stent graft configurations with proximal landing in zones 1, 2, or 3 were enrolled. Preoperative anamnestic and morphological data, clinical outcomes, and aortic modifications 30 days after surgery and at the latest follow-up available were collected. The primary outcome was freedom from proximal endoleak (type IA) comparing the two configurations. Total and detailed endoleak rates, clinical and technical success, intraoperative additional maneuvers, major adverse events, and reinterventions were secondary outcomes. RESULTS: The median follow-up was 4.9 (interquartile range, 2.0-8.1) years. No statistically significant difference between NBS and PBS patients concerning 30-day major adverse events, retrograde aortic dissection, disabling stroke, or late type IA endoleak (10.8% vs 7.8%; P = .597). Aneurysmal disease (P = .026), PLZ diameter of >34 mm (P = .026), aortic tortuosity index of >1.4 (P = .008), type III aortic arch (P = .068), and PLZ thrombus (P = .014) identified as risk factors by univariate Cox regression analysis. PLZ thrombus was the only type IA endoleak risk factor at multivariate Cox regression (P = .016). CONCLUSIONS: We found no statistically significant difference in freedom from type IA endoleak, retrograde dissection, or disabling stroke observed between the NBS and the BS configuration of the Relay endograft. Proximal landing zone thrombotic apposition was a prominent risk factor for type IA endoleak after TEVAR.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Trombose , Humanos , Aorta Torácica/cirurgia , Aorta Torácica/transplante , Correção Endovascular de Aneurisma , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Desenho de Prótese , Fatores de Tempo , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Trombose/etiologia
19.
J Vasc Surg ; 79(5): 1044-1056.e1, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38154605

RESUMO

OBJECTIVE: Global Registry for Endovascular Aortic Treatment (GREAT) is an international prospective multicenter registry collecting real-world data on performance of W. L. Gore thoracic and abdominal aortic endografts. This analysis evaluated the long-term differences in patient survival and device performance in patients undergoing thoracic endovascular aortic repair (TEVAR) for any thoracic aortic pathology. METHODS: From August 2010 to October 2016, 5014 patients were enrolled in GREAT. The population of interest was comprised of only patients treated for thoracic aortic pathologies. Through 5 years, primary outcomes were all-cause and aortic-related mortality, stroke, aortic rupture, endoleaks, migration, fracture, compression, paraplegia, and any reintervention through 5 years, grouped by pathology. Secondary outcomes were reintervention rate and freedom from serious device- and aortic-related events. RESULTS: The 578 patients with thoracic aortic pathologies enrolled in GREAT and identified for this analysis were categorized by common pathologies: thoracic aneurysm (n = 239), thoracic dissection (n = 203), arch (n = 26), and other (n = 110). The mean age of this population was 66.1 ± 12.8 years, and 64.7% were male. Procedure survival was 99.7%. In the overall group, at index procedure to 30 days and 31 days to 5 years, Kaplan-Meier estimates of freedom from all-cause mortality were 99.6% and 66.4%, respectively, and for aortic-related mortality were 97.7% and 94.6%, respectively. Aortic rupture rate was 0.5% (n = 3) at 30 days and 1.4% (n = 8) through 5 years. Stroke and spinal cord ischemic events were 1.9% (n = 11) and 1.6% (n = 9) at 30 days and at 5 years were 3.6% (n = 20), 0.5% (n = 3), respectively. Reinterventions were required in 7.3% (n = 42) at 30 days and 12.4% (n = 69) through 5 years. The number of patients with endoleaks at 30 days was 2.1% (n = 12): n = 3 (1.1%) for each of types IA, 1B, and II; n = 2 (0.3%) for type III; and n = 4 (0.7%) for unspecified. Through 5 years, the percentage of patients was 8.3% (n = 40): n = 15 (3.1%) for type IA; n = 10 (2.1%) for type IB; n = 11 (2.3%) for type II; and n = 9 (1.9%) for unspecified. One patient (0.2%) had stent migration at 30 days (aneurysm group); none were reported through 5 years. There were no incidents of stent compression or fracture from index procedure through 5 years. CONCLUSIONS: Data herein demonstrates durability and support for treatment of thoracic aortic disease with the GORE TAG conformable thoracic stent graft, including no incidents of stent compression/fracture and high freedom from aortic-related mortality. The planned analysis of follow-up to 10 years in GREAT will be beneficial.


Assuntos
Aneurisma da Aorta Torácica , Doenças da Aorta , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Prótese Vascular/efeitos adversos , Endoleak/etiologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Ruptura Aórtica/etiologia , Estudos Prospectivos , Resultado do Tratamento , Fatores de Risco , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/etiologia , Stents/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Sistema de Registros , Acidente Vascular Cerebral/etiologia
20.
J Vasc Surg ; 79(5): 1026-1033, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38154606

RESUMO

BACKGROUND: Endovascular treatment of thoracoabdominal aortic aneurysms has become common, with satisfactory results. Nevertheless, long-term durability remains an issue mainly because of target visceral vessel (TVV) instability. Currently, no covered stent has been approved as a bridging stent graft (BSG), demanding continuous research on this topic. METHODS: This was a multicenter observational retrospective cohort study comparing the midterm results of the Bard Covera Plus and Gore VBX as BSGs during branched endovascular aneurysm repair. The primary outcome was the comparison of the target vessel instability between the two groups. Primary patency, freedom from branch-related type I and III endoleaks and reintervention, and technical and clinical success were considered secondary outcomes. Logistic regression analysis was used to assess the association between selected baseline factors and TVV instability. TVV instability during follow-up was then evaluated using the Kaplan-Meier cumulative function. RESULTS: Three hundred forty-five TVVs in 106 patients were considered suitable for the analysis. Two hundred twenty vessels were stented with the Covera stent graft (64%) and 125 with VBX (36%). Two hundred ninety-nine TVVs received a single BSG, 45 two BSGs, and only 1 three BSGs. Bare metal stent relining was required in 36% of TVVs, mostly in the Covera group (89 [41%] vs 36 [29%]) (P = .030). The primary technical success rate was 96% (331/345), and the assisted primary technical success rate was 99% (342/345). The TVV instability rate within 30 days was 2% (one Covera and five VBX; P = .015). Three BSG occlusions (one Covera and two VBX) and three type Ic endoleaks (three VBX) were detected. The median follow-up was 13.9 months (range, 5.8-25.5 months). Sixteen TVV instabilities were detected during the follow-up. Twelve BSG occlusions (six Covera and six VBX), three type Ic endoleaks (one Covera and two VBX), and one type IIIc endoleak (VBX). The overall target vessel instability rate was 5% (16/342). TVV instability was associated with the use of Gore VBX in the univariable logistic regression (odds ratio, 3.0; 95% confidence interval, 1.1-8.0; P = .027). Aneurysm rupture and aneurysm diameter were also associated with TVV instability in the univariable analysis (P = .002 and P = .008, respectively). The only factor predisposing to TVV instability in the multivariable logistic regression analysis was the use of Gore VBX as a BSG (odds ratio, 2.9; 95% confidence interval, 1.0-8.0; P = .043). Kaplan-Meier analysis showed a significantly higher risk of TVV instability in the VBX group (P < .001). CONCLUSIONS: Overall midterm outcomes in this cohort were satisfactory. Patency rates were similar between the two stents. Nevertheless, VBX seems to be associated with worse TVV instability. These results may be correlated with a higher incidence of type Ic endoleaks, which require an extensive learning curve for correct stent selection and deployment.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Endoleak/etiologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Stents/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...